Click to zoomT105013242003 — Matching position counts allow multi-circuit wiring to be specified against the equipment pin map, while braided sleeving groups the harness for routing. Pitch and position count identify the mechanical format; the circuit assignment identifies its application.
Use it for internal multi-circuit wiring defined by the equipment interface table. Check housing keys and latches at both ends, then map each power, ground and control circuit to its contact number. Matching position counts can still have different wiring, so appearance alone is insufficient for connection.
Braided sleeving groups the harness for routing; it does not by itself establish electromagnetic shielding. Define load, voltage, conductor size and contacts together. For an ATX application, provide the ATX pin definition and the role of each end rather than treating a 24-position housing as complete compatibility evidence.
Send connector part numbers or mating drawings for both ends, the contact map, length, sleeving coverage and quantity. Suntecc can assess nonstandard harness and production requirements from those drawings. Mark any splices, shared circuits or control signals explicitly rather than assuming every position is connected one-to-one.
During sample assembly, review mating, fastening, routing and removal in sequence, then record the selected configuration as a drawing revision for repeat orders. Measure length along the actual route and include connector access, rather than ordering solely from the straight-line distance between the two mating points. Record the connector orientation at each end so repeat orders use the same installation reference.
Discuss this cable assembly · Browse this product category

Click to zoomT105013242003 — Matching position counts allow multi-circuit wiring to be specified against the equipment pin map, while braided sleeving groups the harness for routing. Pitch and position count identify the mechanical format; the circuit assignment identifies its application.
Use it for internal multi-circuit wiring defined by the equipment interface table. Check housing keys and latches at both ends, then map each power, ground and control circuit to its contact number. Matching position counts can still have different wiring, so appearance alone is insufficient for connection.
Braided sleeving groups the harness for routing; it does not by itself establish electromagnetic shielding. Define load, voltage, conductor size and contacts together. For an ATX application, provide the ATX pin definition and the role of each end rather than treating a 24-position housing as complete compatibility evidence.
Send connector part numbers or mating drawings for both ends, the contact map, length, sleeving coverage and quantity. Suntecc can assess nonstandard harness and production requirements from those drawings. Mark any splices, shared circuits or control signals explicitly rather than assuming every position is connected one-to-one.
During sample assembly, review mating, fastening, routing and removal in sequence, then record the selected configuration as a drawing revision for repeat orders. Measure length along the actual route and include connector access, rather than ordering solely from the straight-line distance between the two mating points. Record the connector orientation at each end so repeat orders use the same installation reference.
Discuss this cable assembly · Browse this product category